SPICA arranges its tubes at varying intervals to optimise both towel space and heat. Heights up to 1800 mm let it rise in narrow bathrooms.
- Variable tube spacing
- Up to 1800 mm
- For narrow bathrooms
- Thermal output
- 785 W
- Height range
- 680–1800 mm
Available in all 30 finishes
Finishes →Dimensions
- Width
- 485 mm
- Centres
- 455 mm
- Height
- 680 – 1800 mm
- Slices
- 10 – 22
- Wall to towel-warmer centre
- min.65 – max.90
- Wall to towel-warmer face
- min.80 – max.105
Technical specification
| Model code | SP-500/700 | SP-500/1000 | SP-500/1200 | SP-500/1500 | SP-500/1700 |
|---|---|---|---|---|---|
| Slices | 10 | 14 | 16 | 20 | 22 |
| Gaps | 2 | 3 | 4 | 5 | 6 |
| Height | 680 mm | 1000 mm | 1160 mm | 1480 mm | 1800 mm |
| Centres | 455 mm | 455 mm | 455 mm | 455 mm | 455 mm |
| Width | 485 mm | 485 mm | 485 mm | 485 mm | 485 mm |
| Water content (litres) | 0.9 | 1.2 | 1.5 | 1.9 | 2.2 |
| Output Δt50 (W) | 281 | 365 | 449 | 534 | 618 |
| Output Δt50 (kcal/h) | 242 | 314 | 387 | 460 | 532 |
| Output Δt60 (W) | 357 | 464 | 570 | 678 | 785 |
| Output Δt60 (kcal/h) | 307 | 400 | 491 | 584 | 676 |
| Wall to towel-warmer centre | min.65 – max.90 | min.65 – max.90 | min.65 – max.90 | min.65 – max.90 | min.65 – max.90 |
| Wall to towel-warmer face | min.80 – max.105 | min.80 – max.105 | min.80 – max.105 | min.80 – max.105 | min.80 – max.105 |
Calculator
How many slices, how many watts?
Pick a model and a height, then drag the slice count. Total output, water content and overall length are calculated straight from the catalogue figures.
Slices20
On towel warmers the slice count is fixed by size.
Total output
SPICA →678W
584 kcal/h · Δt60 (90-70-20 °C)
- Water content
- 1.90 litres
- Overall length
- 485 mm
- Height
- 1,480 mm
Figures are for Δt60 (90-70-20 °C), derived from the catalogue's per-slice values. Have a room-by-room heat loss calculation done before final selection.